Menu
Your Cart
"Due to currency devaluation, the prices are subject to change without prior notice. Please confirm the price before placing the order."

KYORITSU KEW 5410 RCD Tester

KYORITSU KEW 5410 RCD Tester price in Paksitan
KYORITSU KEW 5410 RCD Tester
  • Stock Availability: In Stock
  • Model: KYOU-01
Product Views: 8680
Rs. 245,000/-

FEATURES:

  • Measurement of RCD trip time Conducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges.
  • Measurement of trip out current Measuring trip out current by varying   current automatically.
  • Remote Test Enabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected.
  • Voltage Measurement Carrying out a constant measurement of voltage in the range
  • stand-by mode at each Range.
  • Auto-detection of Contact voltage detecting the voltage to earth of Earth electrodes or protective conductors during RCD test - when applying test currents - at measurement using EARTH in order to prevent electrical shocks caused by the damaged earth. Measurement will be ceased at AC50V or more.
  • Dust- and Water-proof dust- and Water-proof construction(designed to IEC 60529 IP54).
  • BacklightFacilitating working at dimly illuminated locations.

 

Document:

KYORITSU KEW 5410 RCD Tester

Product Details
Product Name KYORITSU KEW 5410 RCD Tester
Price Rs. 190,000/-
Computers Specs
Rated Voltage 100V±10%, 200V-10%~+32%, 400V±10%, 50/60Hz
Display Specification
Display 1999 counts (3 1/2digits), Large LCD
Summary
Applicable standards IEC 61010-1 Pollution degree2 CAT III 300V / CAT II 400V IEC 61010-031 IEC 61557-1, 6 IEC 60529 (IP54)
Included Accessories 7128A (Test leads) 7129A (Test lead with alligator clip) 8017 (Long pin) × 2 Cord case, 9121 (Shoulder strap), Instruction manual, R6(AA) × 8
Operating temperature & humidity range 0ºC - 40ºC, relative humidity 85% (no condensation)
Optional Accessories 7100A (Precision measurement cord set)
Overload protection Earth Resistance: 280V AC for 10 seconds across 2 of the 3 terminals Earth Voltage: 300V AC for 1 minute
Safety Standard IEC 61010-1 CAT III 300V Pollution Degree 2, IEC 61557
Storage temperature & humidity range -20ºC - 60ºC, relative humidity 85% (no condensation)
Accuracy (Measurement of RCD trip time - Measurement of trip out current) (Trip Time) (× 5) 1%rdg±3dgt, (x 1) 1%rdg±3dgt, (x 1/2) 1%rdg±3dgt, (AUTO RAMP mA) Test Current at each step -4%~+4% (Trip Time) (× 5) +2%~+8%dgt, (x 1) +2%~+8%dgt, (x 1/2) -8%~-2%dgt (Voltage Measurement) 2%rdg±4dgt
Measuring range Testing time = 0ms~200ms Testing time = 0ms~2000ms Testing time = 0ms~2000ms 40% - 110% of lΔn (goes up by 5%) Testing time 300ms × 15steps (Voltage Measurement) 80V~450V 50/60Hz
Weight Approx. 965g (including batteries)
Insulation Resistance 50MΩ or more / 1000V (between electrical circuit and enclosure)
Range (x 5) (x 1) (x 1/2) (AUTO RAMP mA)
Test Current (approx.) 15/30/50/100mA, 15/30/50/100/200/500mA, 15/30/50/100/200/500mA
Power Source DC 12V / R6(AA)(1.5V) × 8
General Specification
Dimensions 167(L)×186(W)×89(D)mm

Write a review

Note: HTML is not translated!
Bad Good